It's embarrassing to keep guessing at the same cause for so many problems, but if the pressure gauge is accurate and working properly I suspect the pressure switch is not getting a good indication of system water pressure - check for debris clogging. I Have suare D switch lb.
It causes me a lot of trouble when I fill large livestock tanks,can I modify the switch to eliminate the low pressure shut off feature or must i replace the switch. Mike, I'm not sure what trouble you're having with the pressure control switch, and that those details might be diagnostic.
If the pump is short cycling that's usually a pressure tank problem not a switch problem. If the switch is burning up while staying "on" you might need to go to a two-switch system in which the Square-D switch switches on a heavy duty relay that turns on and off the pump. I think it's doing this the whole time the toilet is filling back up? What would cause this?? The pump is new and the pressure tank is old and the pressure switch is new. I run the water the pump clicks on and off every 10 seconds.
I can see condensation line above the half way line on the tank. Whats the problem? My switch cycles constantly and finally sticks and holds contact. Is this an air pressure problem in my water tank? My well is for outdoor irrigation only and has a very small maybe gallon? What adjustment to the pressure switch should I make Short cycling of a water pump describes the pump turning on and off too often when water is running, but not a sticky or misbehaving pressure switch.
Burned switch contacts, a failing switch, a loose connection in the wiring, or a dirt-clogged sensor port on the pressure control switch base or in the tube that conducts water pressure to the switch are more likely at fault. Martin when you swapped in the new switch, if you left a clogged tube on which the switch mounts or that feeds water pressure to the switch, even the sensor port on the new one could be blocked as well.
I'd also check voltage levels. And that the pressure tank is not waterlogged. Jen when the pump turns on and then immediately off it's as if there is no air in the pressure tank - so as water is not very compressible, the system reaches cutoff pressure immediately. If the irrigation system draws water fast enough, or if the pressure tank has an air charge, the symptom you describe should not occur. I think your water tank may be waterlogged. It had never been serviced and had alot of iron build-up.
The shaft had seized. After cleaning it out and putting new seals, it was still able to run ok so I reinstalled it. Then it seemed there was a problem with the pressure switch. I cleaned out the pipes connecting to it and cleaned the switch itself but I wasn't able to get to a setting that wasn't cycling too quickly.
I then looked at the air pressure in the pressure tank. This system is installed in an old 6 floor apartment building. The city supply is about 45psi I wanted to get a cut-on pressure of about 55psi and a cut-off at about The pressure tank Challenger pcr - 85 gallon turned out to be over-charged.
I'm not sure what the pressure was at but it was over 60psi. I let out the air until it got to around Now, cut-on pressure was around 55 and the pump was staying on for around 10 minutes before it reached 70psi but even with the differential nut unscrewed all the way I couldn't get the pump to turn off at 75psi.
I finally unscrewed the main nut and the pump went off but now the cut-on pressure was slightly lower. I'd like to get the cut-on at 60 and cut-off at Help appreciated. Ben, please take another look at the details in the article above about adjusting the pump pressure control switch.
You'll see that the two adjustments on switches that have two do not operate independently, so changing one can require fine tuning the other. Is it true that Preasure pumps fitted in a house with one floor only spoils the washing machine,water heater etc and presure pumps should not be used for such one floored house.
K Sriram I cannot undertand any reason why a well water pump would damage plumbing in a one story house in some way related to the house height. The pressure operating range - psi or psi is within the normal operating range of plumbing fixtures and appliances. In other words, No not in any way I can see. Maybe there is some condition someone knows about that we've never come across? By shutting off the breaker and turning it back on the pressure came back. Is my pump going out.
Start with a completely empty water pressure tank - let air in at ambient area air pressure, and you'll be close. Or install a gauge if there's a port to do so and set the tank pressure to 2 psi below the cut-in pressure on the switch. More likely the pump is twisting and torquing piping. Watch what happens at the equipment when the pump turns on.
I just installed a new pump and water tank with a bladder? All s well but my pump pressure switch is set psi. At present the pressure in the tank is set at 18 psi and should be set at 28 psi from what i read. You think that i should drain the tank and put the air in the tank up to the 28 psi, or can i just leave it the way it is.
Does it hurt the system by having a lower pressure in the tank then what is called for. Everything seems to be running fine at it's current cut in and cut off but the pressure is a little weak. I am unsure what to do because everything I have read states that the cut off pressure should not exceed 60 PSI. Mark, 94 PSI is a very high cut-out pressure and risks leaks or a burst pipe; if something indeed bursts someone nearby could be injured.
Make an independent measurement of water pressure and tell me what it is when the pump has cut out and no water is being run in the building.
Here are a couple of reasons you should be paying attention to small leaks. Find out how tree roots make their way into your pipes and how to get rid of them without doing harm to the tree itself. You must have javascript enabled in your browser to utilize the functionality of this website.
Due to the ongoing global supply chain constraints, some products may be temporarily sold out. Take Quiz. Smart Water Faucets. Smart Water Shutoff Sold Out.
Smart Water Detector. Shop All. Flo By Moen App. Setting up. Smart Water Shutoff Support. Smart Water Detector Support. Flo App Support. General Inquiries. Login or Register. Here are some hard water red flags: Clogged shower head. Residues in the kitchen and bathroom. Clogged pipes and drains. Upgrade to a Constant Pressure System Sometimes with well water systems, running multiple fixtures at the same time will cause a sudden drop in pressure.
Articles You May Like. How to Save Money on Leak Detection? How to Prevent Mold and Mildew Make sure to put these practices into place to prevent mildew and mold growth to keep your home and your loved ones safe. The stealthy damage leads to costly repair bills. I am curious if I can set the pressure higher or if I risk damaging the system.
The majority of the plumbing in the house is PEX. Tank specs:. Pressure switch:. Normally, most household plumbing fixtures especially toilet valves prefer a pressure of no more than 80 PSI. Your pipes are nearly always not the limiting factor. Most well pump controllers have a fixed 20PSI swing from on to off, but many can be adjusted so they can swing , , , , The volume of water stored in your pressure tanks becomes less as the pressure is raised - a captive air tank swinging from 40 to 20 PSI stores far more water than one swinging from 80 to 60 PSI.
This matters because more pump starts is one of the factors that leads eventually to pump death and replacement, always a fun time. So if you raise the system pressure, you should probably also increase your storage tank volume to prevent having lots of very short pump cycles. Switching over to a "constant pressure" or "nearly constant pressure" system is another alternative, though it can be costly.
If you change system pressure, you need to change precharge air pressure in captive air tanks typically about PSI less than the lower cut-in pressure - ie, 58 lb for an setting. You should observe system pressure as water is used - a properly functioning PSI system should drop to about 40, switch on the pump and raise to 60, switch off the pump and drop to 40 as water is used.
When no water is used the system pressure should hold steady. If you turn off all other water use and measure exactly how much water is needed to drop from 60 to 40 you can gauge the health and current storage capacity of your pressure tanks.
If you measure the time it takes to refill from without drawing any more water you will know your pumping rate and if it takes less than a minute, conventional wisdom is that you already need more storage capacity. You didn't say where your pressure switch is or what the elevation of the house and switch is.
I'm assuming usually a bad thing that the switch is near the tanks based on the picture, but the house could be higher than the switch. Water pressure changes by 0. Let the system build up pressure and then measure the static water pressure no water being used and pump off at the switch or well hopefully you have a spigot there and at the house.
Check for any differential and factor that into your pressure calculation when adjusting your pressure. You said the well and tanks are about feet from the house so you can also have a pressure drop due to the distance of piping and size of pipe used - only when the water is being used, statically you will not see this.
If the switch and the house are about level and they used 2" pipes, then it probably doesn't matter much if the tanks are at the well or the house. Yes, I know this question is old OK, lets start by actually answering your question That said, here are things to consider. First though, I need to correct an answer that was given above.
Volume is volume. It would require extraordinarily high pressure to compress water sufficiently to impact volume capacity of a rigid container. Higher pressure puts more stress on plumbing. You said you have PEX, which means your plumbing is newer good thing. As long as you are not above 80, you are at "safe" levels. I personally prefer to stay well below that threshold no more than